Figure 8 | Cardiovascular Ultrasound

Figure 8

From: Doppler echocardiography and myocardial dyssynchrony: a practical update of old and new ultrasound technologies

Figure 8

Methodology of calculation of Dyssynchrony Index and is ability in predicting LV inverse remodeling. In the upper panel methodology of calculation of Dyssynchrony Index, i.e., the standard deviation of Ts (Ts-SD) measured in the basal and mid-segments visualizable in the apical views. In the lower panel, Ts-SD shows the ability to predict an effective LV inverse remodeling after CRT (lower panel). Values of TS-SD > 32.6 (black triangles) predict an effective LV reverse remodeling (DLVVs = delta left ventricular end-systolic volumes) after CRT. Patients with pre-CRT values of Ts-SD < 32.6 (empty circles) do not present significant LV inverse remodeling at follow-up. (Modified from Yu CM et al, Am J Cardiol 2003;91:684–688)