Skip to main content

Table 1 Diagnostic value of 2D Echo and coronary flow reserve

From: Coronary flow reserve in stress-echo lab. From pathophysiologic toy to diagnostic tool

 

Sensitivity

CI 95%

Specificity

CI 95%

Accuracy

CI 95%

2D Echo

74%

64–84%

91%

87–96%

86%

82–91%

Coronary Flow Reserve (cut-off = 2)

89%

81–96%

77%

71–84%

81%

76–86%

Coronary Flow Reserve (cut-off = 1,9)

81%

72–90%

84%

79–90%

83%

79–88%

Coronary Flow Reserve (cut-off = 1,8)

69%

58–79%

90%

85–95%

83%

79–88%

Coronary Flow Reserve (cut-off = 1,7)

63%

52–74%

97%

94–99%

86%

82–91%

Coronary Flow Reserve (cut-off = 1,6)

50%

38–61%

100%

-

85%

80–89%

Coronary Flow Reserve (cut-off = 1,5)

30%

19–41%

100%

-

79%

73–84%

2D Echo / CFR cut-off = 1,9

90%

81–98%

94%

91–98%

93%