Skip to main content

Table 3 Correlations and t-tests

From: A new technique for assessing arterial pressure wave forms and central pressure with tissue Doppler

 

Tono (mmHg)

TDI (mmHg)

Difference (mmHg)

p

Control (33)

103 ± 9

101 ± 9

2.08 ± 2.2

< .0001

HTN (28)

132 ± 22

122 ± 19

9.23 ± 6.3

< .0001

DM (10)

114 ± 10

109 ± 9

5.18 ± 3.0

< .0001

RT (10)

108 ± 12

100 ± 11

7.50 ± 7.7

< .01

CHF (10)

91 ± 10

87 ± 8

3.38 ± 2.6

< .003

  1. Subgroup analysis and paired differences between carotid tonometry and tissue Doppler. Tono – tonometry