Table 4 Correlations of total average diastolic longitudinal displacement with peak average diastolic velocities and average systolic longitudinal displacement for subjects with LV hypertrophy and no diastolic dysfunction and a first and second degree of diastolic dysfunction

From: Total average diastolic longitudinal displacement by colour tissue doppler imaging as an assessment of diastolic function

Comparison

DDF 0

DDF 1

DDF 2

Pearson Correlation

P-value

Pearson Correlation

P-value

Pearson Correlation

P-value

e’ and TT-e’

0.92

<0.001

0.77

<0.001

0.67

<0.05

a’ and TT-a’

0.89

<0.001

0.81

<0.001

0.88

<0.001

e’ + a’ and TT-e’ + TT-a’

0.81

<0.001

0.81

<0.001

0.88

<0.001

TT-e’/TT-a’ and e’/a’

0.95

<0.001

0.75

<0.001

0.76

<0.001

TT-s’ and TT-e’ + TT-a’

0.53

<0.05

0.62

<0.05

0.79

<0.001

TT-e’ + TT-a’ and s’

0.46

0.06

0.40

0.09

0.80

<0.001

  1. e’ early diastolic tissue velocity by TDI measured at the mitral annulus, a’ late diastolic tissue velocity by TDI measured at the mitral annulus, s’ systolic tissue velocity by TDI measured at the mitral annulus, TT-e’ early diastolic displacement measured at the mitral annulus, TT-a’ late diastolic displacement measured at the mitral annulus, TT-s’ systolic displacement measured at the mitral annulus