Skip to main content

Table 3 Published correlations between ultrasound measurements of IVC collapsibility index and CVP or RAP in spontaneously ventilating patients

From: The efficacy of sonographic measurement of inferior vena cava diameter as an estimate of central venous pressure

Type of inspiration

Study

N

Mean CVP or RAP

Correlation coefficient

p-value

Comments

Passive

Taniguchi et al., [19]

90

8.0

−0.57

<0.05

Study reports median CVP/RAP

Zhang et al., [21]

72

3.0

−0.27

0.017

 

Prekker et al., [26]

65

7.0

−0.40

<0.05

Study reports median CVP/RAP

Yildirimturk et al., [15]

22

9.7

−0.49

<0.05

 

Nagdev et al., [28]

73

10.5

−0.74

<0.05

 

Brennan et al., [18]

91

7.0

−0.50

a

 

Kircher et al., [3]

83

a

−0.75

a

 

Moreno et al., [17]

65

a

−0.71

a

 

Sniff

Taniguchi et al., [19]

90

8.0

−0.63

<0.05

Study reports median CVP/RAP

Tsutsui et al., [22]

71

13.0

−0.41

<0.0001

 

Patel et al., [16]

34

11.0

−0.49

0.006

 

Brennan et al., [18]

91

7.0

−0.54

a

 

Nagueh et al., [31]

23

9.0

−0.76

<0.001

 
  1. adata not available